Basic Info.
Model NO.
GME-Coupling
Envrionment Management System
ISO9001/14001
Certificate
Ce/RoHS/SGS
Tolerance
+/- 0.05mm
Model Number
Gme-Coupling
Magnetization Direction
Axial/Radial/Multi-Poles Magnetization
Working Temp.
80-200 Degree Centigrade
Transportation
by Sea, by Air, by Express
Payment
T/T, Paypal, Western Union
Lead Time
15-25days
Transport Package
Carton, Wood Case, Anti-Magnetized Package
Specification
Customized made
Trademark
GME
Origin
Zhejiang Ningbo/ Fujian Xiamen
HS Code
850511100
Production Capacity
1000000 Sets
Product Description
Hot sale: low noise , no leakage, no additional cost for coupling shafts magnetic pump coupling permanent magnetic coupling
Please send us the following information.
1. Motor output power(KW)
2. Motor speed(RPM)
3. The torque of the magnetic coupling
4. Working pressure of the housing(isolation sleeve)
5. Working temperature of magnetic coupling
6. Technical drawing of the output part connector (usually motor)
7. Technical drawing of the input part connector (usually pump)
Introduction of coupling shafts magnetic pump coupling permanent magnetic coupling
The magnetic shaft coupling is a new kind of coupling, which connects motor and machine by permanent magnetic force.
They consist of an external rotor, internal rotor and isolating covers.
They work in the sealed magnetic drive pumps, which transporting volatile, flammable, explosive and toxic solutions with no leakage.
These magnetic shaft couplings can be used to connect gear pumps, screw pumps, centrifugal pumps, etc. with all types of the electric motor or gear box.
Magnetic shaft coupling is widely used in various industries and fields, such as chemical, papermaking, foodstuff, pharmacy, and so on.
How Does A Magnetic Coupling Work
A magnetic coupling consists of two magnetic assemblies and isolation cover. One is the external assembly (the driver magnet) and the other is the internal assembly (the driven magnet). The external assembly is connected to a motor and the internal assembly is directly attached to the pump input drive shaft. Since the internal magnet is isolated within the pump case, seals and therefore leaks are eliminated.
The coupling deflects angularly and the magnets create a force of simultaneous attraction and repulsion while the magnetic coupler assembly is working. This force is used to transfer torque from the motor to the pump drive shaft. This permanent magnet coupling creates neither slippage nor induction current during rotation.
The seals for metering pumps, feed pumps, and chemical day tank agitators can all be replaced with a permanent magnet coupling to eliminate seal leakage and downtime associated with seal replacement. The internal submerged magnet is of "sealed" construction.
Advantages of coupling shafts magnetic pump coupling permanent magnetic coupling
» Elimination of fluid leakage from the pump shaft.
» Vibrations are not transmitted to the pump.
» No maintenance required for magnetic couplings.
» Using magnetic couplings allows the use of standard pumps without expensive mechanical seals.
» No additional cost for purchasing mechanical seal spare parts and maintenance.
Specification of coupling shafts magnetic pump coupling permanent magnetic coupling
Application of coupling shafts magnetic pump coupling permanent magnetic coupling
The ability to hermetically separate two areas whilst continuing to transmit mechanical power from one to the other makes these couplings ideal for applications where prevention of cross-contamination is essential. For instance: hydraulic sectors, dosing systems, compressors, sterilizers, industrial ovens, biotechnology, subsea equipment, pharmaceutical industry, chemical industry, food industry, generators, and mixers.
Operation principles of coupling shafts magnetic pump coupling permanent magnetic coupling
The magnetic coupling works by using the power generated by permanent magnets. No external power supply is needed. These are permanent magnets, not electro magnets.
Packing Method of coupling shafts magnetic pump coupling permanent magnetic coupling
Double strength Corrugated Carton and Wood case Sea Packing.
Please send us the following information.
1. Motor output power(KW)
2. Motor speed(RPM)
3. The torque of the magnetic coupling
4. Working pressure of the housing(isolation sleeve)
5. Working temperature of magnetic coupling
6. Technical drawing of the output part connector (usually motor)
7. Technical drawing of the input part connector (usually pump)
Introduction of coupling shafts magnetic pump coupling permanent magnetic coupling
The magnetic shaft coupling is a new kind of coupling, which connects motor and machine by permanent magnetic force.
They consist of an external rotor, internal rotor and isolating covers.
They work in the sealed magnetic drive pumps, which transporting volatile, flammable, explosive and toxic solutions with no leakage.
These magnetic shaft couplings can be used to connect gear pumps, screw pumps, centrifugal pumps, etc. with all types of the electric motor or gear box.
Magnetic shaft coupling is widely used in various industries and fields, such as chemical, papermaking, foodstuff, pharmacy, and so on.
How Does A Magnetic Coupling Work
A magnetic coupling consists of two magnetic assemblies and isolation cover. One is the external assembly (the driver magnet) and the other is the internal assembly (the driven magnet). The external assembly is connected to a motor and the internal assembly is directly attached to the pump input drive shaft. Since the internal magnet is isolated within the pump case, seals and therefore leaks are eliminated.
The coupling deflects angularly and the magnets create a force of simultaneous attraction and repulsion while the magnetic coupler assembly is working. This force is used to transfer torque from the motor to the pump drive shaft. This permanent magnet coupling creates neither slippage nor induction current during rotation.
The seals for metering pumps, feed pumps, and chemical day tank agitators can all be replaced with a permanent magnet coupling to eliminate seal leakage and downtime associated with seal replacement. The internal submerged magnet is of "sealed" construction.
Advantages of coupling shafts magnetic pump coupling permanent magnetic coupling
» Elimination of fluid leakage from the pump shaft.
» Vibrations are not transmitted to the pump.
» No maintenance required for magnetic couplings.
» Using magnetic couplings allows the use of standard pumps without expensive mechanical seals.
» No additional cost for purchasing mechanical seal spare parts and maintenance.
Specification of coupling shafts magnetic pump coupling permanent magnetic coupling
Item | Internal Rotor(mm) | External Rotor(mm) | Isolating Covering(mm) | |||||||||||||||||
A | B | C | D | E | F | G | Shaft Pin | H | I | J | L | N | M | P | Q | R | S | T | U | |
GME03-3LM00 | Φ35 | - | Φ10 | 26 | - | 18 | - | M6X12 | Φ42 | Φ60 | Φ50 | 46 | 6-M4 | Φ40 | Φ50 | 4-Φ5.4 | Φ38 | Φ60 | 6 | 6 |
GME03-5MM00 | Φ42 | - | Φ12 | 27 | 4 | 18 | 13.8 | M6X16 | Φ49 | Φ72 | Φ60 | 46 | 4-Φ6.7 | Φ52 | Φ60 | 4-Φ6.7 | Φ44 | Φ74 | 8 | 8 |
GME03-16LM00 | Φ56 | - | Φ12 | 45 | 4 | 25 | 13.8 | M6X16 | Φ63 | Φ89 | Φ80 | 75 | 6-M5 | Φ70 | Φ75 | 4-Φ6.7 | Φ58 | Φ89 | 8 | 8 |
GME03-16LM01 | Φ56 | - | Φ12 | 45 | 4 | 25 | 13.8 | M6X16 | Φ63 | Φ89 | Φ80 | 75 | 4-M5 | Φ70 | Φ75 | 4-Φ6.7 | Φ58 | Φ89 | 6 | 10 |
GME03-16MM00 | Φ56 | - | Φ12 | 45 | 4 | 25 | 13.8 | M6X16 | Φ63 | Φ89 | Φ80 | 75 | 6-M5 | Φ70 | Φ75 | 4-Φ6.7 | Φ58 | Φ89 | 8 | 8 |
GME03-22LM00 | Φ88 | - | Φ20 | 29 | 6 | 25 | 22.8 | M8X20 | Φ97 | Φ122 | Φ110 | 70 | 8-M6 | Φ98 | Φ108 | 6-Φ6.7 | Φ91 | Φ122 | 8 | 8 |
GME03-30LM00 | Φ88 | - | Φ20 | 48 | 6 | 30 | 22.8 | M8X20 | Φ97 | Φ122 | Φ110 | 81 | 8-M6 | Φ98 | Φ108 | 6-Φ6.7 | Φ91 | Φ122 | 8 | 8 |
GME03-40LM00 | Φ101 | - | Φ25 | 49 | 8 | 28 | 28.3 | M10X20 | Φ109 | Φ140 | Φ124 | 83 | 8-M8 | Φ110 | Φ126 | 8-Φ6.7 | Φ103 | Φ140 | 12 | 6 |
GME03-50LM00 | Φ107 | - | Φ20 | 70 | 6 | 30 | 22.8 | M6X16 | Φ113.4 | Φ145 | Φ135 | 80 | 4-M6 | Φ126 | Φ133 | 12-Φ8.7 | Φ109 | Φ153 | 12 | 15 |
GME03-65LM00 | Φ101 | - | Φ25 | 77 | 8 | 45 | 28.3 | M10X20 | Φ109 | Φ140 | Φ124 | 111 | 8-M8 | Φ110 | Φ126 | 8-Φ6.7 | Φ103 | Φ140 | 12 | 6 |
GME03-80LM00 | Φ106 | - | Φ32 | 65 | 10 | 21 | 36.5 | M6X25 | Φ115 | Φ145 | Φ135 | 82 | 4-M6 | Φ127 | Φ135 | 6-Φ8.7 | Φ110 | Φ153 | 13 | 18 |
GME03-80LM00 | Φ141 | Φ92 | Φ40 | 65 | 12 | 45 | 43.3 | M12X25 | Φ152 | Φ180 | Φ168 | 100 | 8-M8 | Φ154 | Φ164 | 8-Φ6.7 | Φ145 | Φ180 | 12 | 8 |
GME03-100LM00 | Φ131 | Φ82 | Φ32 | 80 | 10 | 24.5 | 35.3 | M8X35 | Φ139 | Φ170 | Φ160 | 100 | 4-M6 | Φ152 | Φ158 | 8-Φ8.7 | Φ133 | Φ178 | 14 | 21 |
GME03-110LH00 | Φ141 | Φ92 | Φ40 | 85 | 10 | 50 | 43.3 | M12X25 | Φ152 | Φ184 | Φ168 | 115 | 12-M8 | Φ156 | Φ164 | 12-Φ6.7 | Φ145 | Φ180 | 12 | 3 |
GME03-110LM00 | Φ141 | Φ92 | Φ35 | 80 | 10 | 55 | 38.3 | M12X25 | Φ152 | Φ180 | Φ168 | 115 | 12-M8 | Φ154 | Φ164 | 12-Φ6.7 | Φ145 | Φ180 | 12 | 3 |
GME03-140LM00 | Φ141 | Φ92 | Φ40 | 110 | 12 | 80 | 43.3 | M12X25 | Φ152 | Φ190 | Φ170 | 145 | 12-M10 | Φ154 | Φ164 | 12-Φ6.7 | Φ145 | Φ180 | 12 | 3 |
GME03-180LM00 | Φ141 | Φ92 | Φ40 | 140 | 12 | 95 | 43.3 | M12X25 | Φ152 | Φ190 | Φ170 | 175 | 12-M10 | Φ154 | Φ164 | 12-Φ6.7 | Φ145 | Φ180 | 12 | 3 |
GME03-220LM00 | Φ141 | Φ92 | Φ48 | 160 | 14 | 110 | 51.8 | M12X25 | Φ152 | Φ190 | Φ170 | 195 | 12-M10 | Φ154 | Φ164 | 12-Φ6.7 | Φ145 | Φ180 | 12 | 3 |
GME03-300LM00 | Φ162 | - | Φ65 | 100 | 18 | 60 | 69.4 | Φ170 | Φ198 | Φ188 | 123 | 12-M6 | Φ180 | Φ192 | 12-Φ11 | Φ163.5 | Φ218 | 16 | 10 | |
GME03-400LH00 | Φ195 | - | Φ70 | 127 | 20 | 107 | 79.9 | M12X25 | Φ203 | Φ234 | Φ222 | 152 | 6-M6 | Φ212 | Φ164 | 12-Φ11 | Φ198 | Φ278 | 16 | 22 |
Application of coupling shafts magnetic pump coupling permanent magnetic coupling
The ability to hermetically separate two areas whilst continuing to transmit mechanical power from one to the other makes these couplings ideal for applications where prevention of cross-contamination is essential. For instance: hydraulic sectors, dosing systems, compressors, sterilizers, industrial ovens, biotechnology, subsea equipment, pharmaceutical industry, chemical industry, food industry, generators, and mixers.
Operation principles of coupling shafts magnetic pump coupling permanent magnetic coupling
The magnetic coupling works by using the power generated by permanent magnets. No external power supply is needed. These are permanent magnets, not electro magnets.
Packing Method of coupling shafts magnetic pump coupling permanent magnetic coupling
Double strength Corrugated Carton and Wood case Sea Packing.